SNMP interface card An SNMP interface card can be placed in the rear panel of the UPS, and allows the data interface to be connected directly to an Ethernet network. When this option is installed the ComProt communication link (serial communication) is no longer available to the user. Relay card The relay plug-in card can be installed in the rear panel of the UPS. The card is provided with four potential free contacts representing: battery low, bypass active, utility failure and general alarm. Alarm boxes An interface box linked to the ComConnect port, the VIC/RELAYBOX/01 translates the ComConnect signals to five independent changeover contacts, with a maximum switching capacity of 230V/5A each. Wall mounted plastic alarm boxes are available for remote audible and visual alarm indication. Connectivity products A splitter box translates information from the ComConnect to several computers. Interface kits (cables and/or software) are available for operating systems supporting JAVA and most commonly used network operating systems, including Novell, UNIX, VMS, Windows platforms, IBM AS/400, IBM OS/2, LINUX. Please contact your dealer for specific information. Battery extension packs Except for the 3-11 model, the LP 11 UPS can be equipped with additional batteries to increase the runtime of the unit. These additional batteries are housed in a separate battery pack. Additional batteries will increase the recharging time for the unit. All other operational information is the same. Battery packs can be connected in parallel to increase the runtime. DC connectors make installation of battery packs easy and simple. Input converter (rectifier + power factor correction) Nominal AC input voltage 220 - 240V L + N Input frequency range 40 - 70Hz Power factor >0.99 THDi <10% Nominal input current (no charging, Uin = nominal) A 12.1 19.8 23.7 31.6 39 Inrush current None DC output voltage 380 V Battery charger Battery charging characteristic IU (DIN 41773) constant current charging until floating voltage, thenconstant voltage charging + boost charge DC input voltage range 350 - 450 V DC output voltage 162.5/177V (3kVA), 271/295.5V (5/6/8/10kVA) Output current limitation Adc 2.0 2.0 2.0 3.0 3.0 Recharge time 1.5 - 3 hours for 80% capacity Battery data Battery type Sealed and maintenance free (VRLA=Valve Regulated Lead Acid) Float voltage at 25°C 162.5 / 271 V Number of 12V batteries (in standard version) 12x7Ah (3kVA) 20x7Ah (5/6kVA) 20x12Ah (8/10kVA) Standard backup time at nominal load PF=0.8 min 10 10 8 11 8 Standard backup extensions See table on page 4 Modifications reserved Page 2/5 TDS_LPE_11X_3K0_10K_1GB_V0511.doc Technical Data Sheets LP 11 Series 3-5-6-8-10 kVA Output converter (inverter) Input voltage range 270 - 400 V Nominal output power at PF=0.8 kVA 3 5 6 8 10 Nominal output power with resistive load kW 2.4 4 4.8 6.4 8 Nominal AC output voltage 220 / 230 / 240V Output voltage waveform Sine wave
|